 |
Previous Improvements to Sulsim®
Sulphur Experts has incorporated many
features into the latest release of Sulsim.
Improvements and bug-fixes in Sulsim® from the previous versions (versions
5.13, 5.08, 5.05, 5.03, 5.02) include the following: (All of these fixes are
incorporated into Sulsim® 6)
-
32-bit
Compilation (more ...)
-
Improved
Memory Allocation to Virtually Eliminate Program Crashes
(more ...)
-
Refined
Reaction Furnace Empirical Correlations
(more ...)
-
Correction
to the Water Compensation Calculation
(more ...)
-
Corrections
to the Temperature Convergence Routine of Direct Reheater
(more ...)
-
Sulsim®
5.13 corrected an error in the temperature convergence routines. In previous
versions, the reheater would not necessarily converge to the value input by the user
if there was liquid sulphur in the inlet process gas stream. This was a result of
incorrect handling of the enthalpy of this two phase process stream.
-
Corrections
to the Enthalpy Balance of Selective Oxidation Reactors
(more ...)
- User
defined convergence criteria
(more ...)
-
Sulsim® 5.08 and 5.13
allow the user to specify the convergence criteria for iterative processes. Depending on
the User specified criteria, Sulsim® iteration
cycles can be altered to loosen the convergence cycle and speed up the case run.
- Stream
flow inputs in units of mass and volume
(more ...)
- Stream flow rates for
Sulsim®
5.08 and 5.13
can be entered in standard units of mass or volume. A new button appears on the
left-hand side of the flow input dialog box, allowing the user to toggle between "Gas
Flow (mass)" or "Gas Flow (molar)". This
allows the user to input any stream flow in either units of mass or in units
of volume
- Improved
Help file
(more ...)
-
Sulsim®
5.08 and 5.13
features an expanded Help file that includes an "Advanced Features and Tips"
section. The new section explains some of the advanced features of Sulsim, including:
- when and how to set-up multiple trains using
Sulsim®
5.08/5.13
- optimizing
Sulsim®
5.08/5.13
for speed or accuracy
- a discussion of possible errors and troubleshooting
- Flexible
air control criteria
(more ...)
-
Sulsim®
5.08 and 5.13
allow the User to specify certain tail gas conditions using the Air Demand Analyser unit,
to match actual process data or to set non-standard applications. The Air Demand Analyser
dialog box allows the User to select the method of air control by setting the tail gas
conditions, based on "Air Demand", "H2S/SO2
ratio", "H2S Concentration" or "SO2
Concentration"
- Auto-save
Feature
(more ...)
- Should
Sulsim®
5.08 and 5.13
stop executing and the User be unable to continue to work with the case upon re-starting
the program, Sulsim®
5.08 and 5.13
will identify any cases which were not properly terminated. These cases will be available
to work with.
- Improved Bypass Stream
(more ...)
- A bypass stream may now have a fractional bypass of the
entire stream or a fraction bypass of individual components.
- Bug Fixes
from previous versions
(more ...)
- The following bugs have been fixed from Sulsim®
versions 5.02/5.03/5.05 as of March 16,1999:
- Multiple Train Installation: Sulsim®
allows a total of four "trains" to be installed in a single case. In the
original release, if a train was installed and subsequently deleted, the
"position" for that train was lost, thus limiting the total number of trains to
three. This problem has been resolved in Sulsim®
5.08 and 5.13.
- Thermal Incinerator: Sulsim®
allow for the User to specify the amount of fuel gas flow to this unit. If the User
specified a fuel gas flow of 0.000 (units),
Sulsim®
incorrectly calculated a non-zero value. This problem has been resolved in
Sulsim®
5.08 and 5.13.
- Performance Table Summary: In previous
versions, the Performance Summary Table incorrectly calculated the cumulative conversion
and recovery efficiency values when bypasses and multiple trains where involved. The
Performance Summary in Sulsim®
5.08 and 5.13 has been
repaired to ensure the correct reporting of these values.
|
 |